Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 33
Filtrar
1.
J Cardiovasc Thorac Res ; 16(1): 15-20, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38584662

RESUMO

Introduction: The present study sought to compare the diagnostic accuracy and radiation dose of ECG-gated, ultra-fast, low-dose, high-pitch, spiral (FLASH) mode versus conventional, ECG-gated, sequential coronary artery calcium (CAC) scoring in patients with suspected coronary artery disease (CAD). Methods: The study included 120 patients who underwent both conventional scanning and FLASH mode scanning and were subdivided into derivation and validation cohorts. In the conventional sequential (step-and-shoot) protocol, prospective ECG-gated, non-contrast acquisition was performed at 70% of R-R interval. The spiral (FLASH) mode utilized a high-pitch and high-speed gantry rotation scanning mode where acquisition of the entire heart was done within a single cardiac cycle with prospective ECG-gating at 70% of R-R interval. Results: Correlation between CAC scores derived from conventional (cCAC) and FLASH mode (fCAC) in derivation cohort was excellent (r=0.99; P<0.001). A linear regression model was used to develop a formula for deriving the estimated CAC score (eCAC) from fCAC (eCAC=0.978 x fCAC). In validation cohort, eCAC showed excellent agreement with cCAC (ICC=0.9983; 95%CI: 0.9972 - 0.9990). Excellent agreement for risk classification (weighted kappa=0.93898; 95%CI: 0.86833 - 1.0000) was observed with 95% (57/60) scores falling within the same risk category. Effective dose was significantly lower in FLASH mode (conventional, 0.58±0.21 mSv vs. FLASH, 0.34±0.12 mSv; P<0.0001). Conclusion: CAC scoring using FLASH mode is feasible with high accuracy and shows excellent agreement with conventional CAC scores at significantly reduced radiation doses.

2.
Eur Radiol ; 2024 Jan 10.
Artigo em Inglês | MEDLINE | ID: mdl-38195730

RESUMO

OBJECTIVES: Assessment of myocardial strain by feature tracking magnetic resonance imaging (FT-MRI) in human fetuses with and without congenital heart disease (CHD) using cardiac Doppler ultrasound (DUS) gating. METHODS: A total of 43 human fetuses (gestational age 28-41 weeks) underwent dynamic cardiac MRI at 3 T. Cine balanced steady-state free-precession imaging was performed using fetal cardiac DUS gating. FT-MRI was analyzed using dedicated post-processing software. Endo- and epicardial contours were manually delineated from fetal cardiac 4-chamber views, followed by automated propagation to calculate global longitudinal strain (GLS) of the left (LV) and right ventricle (RV), LV radial strain, and LV strain rate. RESULTS: Strain assessment was successful in 38/43 fetuses (88%); 23 of them had postnatally confirmed diagnosis of CHD (e.g., coarctation, transposition of great arteries) and 15 were heart healthy. Five fetuses were excluded due to reduced image quality. In fetuses with CHD compared to healthy controls, median LV GLS (- 13.2% vs. - 18.9%; p < 0.007), RV GLS (- 7.9% vs. - 16.2%; p < 0.006), and LV strain rate (1.4 s-1 vs. 1.6 s-1; p < 0.003) were significantly higher (i.e., less negative). LV radial strain was without a statistically significant difference (20.7% vs. 22.6%; p = 0.1). Bivariate discriminant analysis for LV GLS and RV GLS revealed a sensitivity of 67% and specificity of 93% to differentiate between fetuses with CHD and healthy fetuses. CONCLUSION: Myocardial strain was successfully assessed in the human fetus, performing dynamic fetal cardiac MRI with DUS gating. Our study indicates that strain parameters may allow for differentiation between fetuses with and without CHD. CLINICAL RELEVANCE STATEMENT: Myocardial strain analysis by cardiac MRI with Doppler ultrasound gating and feature tracking may provide a new diagnostic approach for evaluation of fetal cardiac function in congenital heart disease. KEY POINTS: • MRI myocardial strain analysis has not been performed in human fetuses so far. • Myocardial strain was assessed in human fetuses using cardiac MRI with Doppler ultrasound gating. • MRI myocardial strain may provide a new diagnostic approach to evaluate fetal cardiac function.

3.
Eur Radiol ; 34(1): 214-225, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37530810

RESUMO

OBJECTIVES: To evaluate the prevalence of intra-myocardial fatty scars (IMFS) most likely indicating previous silent myocardial infarction (SMI), as detected on coronary artery calcium (CAC) computed tomography (CT) scans in diabetic patients without history of coronary heart disease (CHD). METHODS: Diabetic patients screened for silent coronary insufficiency in a tertiary-care, university hospital between Jan-2015 and Dec-2016 were categorized according to their CAC score in two groups comprising 242 patients with CACS = 0 and 145 patients with CACS ≥ 300. CAC-CT scans were retrospectively evaluated for subendorcardial and transmural IMFS of the left ventricle. Adipose remodeling, patients' characteristics, cardiovascular risk factors and metabolic profile were compared between groups. RESULTS: Eighty-three (21%) patients with IMFS were identified, 55 (37.9%) in the group CACS ≥ 300 and 28 (11.6%) in the CACS = 0 (OR = 4.67; 95% CI = 2.78-7.84; p < 0.001). Total and average surface of IMFS and their number per patient were similar in both groups (p = 0.55; p = 0.29; p = 0.61, respectively). In the group CACS ≥ 300, patients with IMFS were older (p = 0.03) and had longer-lasting diabetes (p = 0.04). Patients with IMFS were older and had longer history of diabetes, reduced glomerular filtration rate, more coronary calcifications (all p < 0.05), and higher prevalence of carotid plaques (OR = 3.03; 95% CI = 1.43-6.39, p = 0.004). After correction for other variables, only a CACS ≥ 300 (OR = 5.12; 95% CI = 2.66-9.85; p < 0.001) was associated with an increased risk of having IMFS. CONCLUSIONS: In diabetic patients without known CHD, IMFSs were found in patients without coronary calcifications, although not as frequently as in patients with heavily calcified coronary arteries. It remains to be established if this marker translates in an upwards cardiovascular risk restratification especially in diabetic patients with CACS = 0. CLINICAL RELEVANCE STATEMENT: In diabetic patients without history of coronary heart disease, intramyocardial fatty scars, presumably of post-infarction origin, can be detected on coronary artery calcium CT scans more frequently, but not exclusively, if the coronary arteries are heavily calcified as compared to those without calcifications. KEY POINTS: • Intramyocardial fatty scars (IMFS), presumably of post-infarction origin, can be detected on coronary artery calcium (CAC) CT scans more frequently, but not exclusively, in diabetic patients with CACS ≥ 300 as compared to patients CACS = 0. • Patients with IMFS were older and had longer history of diabetes, reduced glomerular filtration rate, and more coronary calcifications. • Carotid plaques and CACS ≥ 300 were associated with an increased risk of having IMFS, about three and five folds respectively.


Assuntos
Calcinose , Doença da Artéria Coronariana , Diabetes Mellitus , Infarto do Miocárdio , Calcificação Vascular , Humanos , Cálcio/metabolismo , Angiografia Coronária/métodos , Estudos Retrospectivos , Cicatriz , Fatores de Risco , Doença da Artéria Coronariana/complicações , Doença da Artéria Coronariana/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Infarto do Miocárdio/complicações , Infarto do Miocárdio/diagnóstico por imagem , Diabetes Mellitus/epidemiologia , Calcinose/complicações , Calcinose/diagnóstico por imagem , Calcinose/epidemiologia , Valor Preditivo dos Testes
4.
J Cardiovasc Thorac Res ; 15(3): 193-195, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38028720

RESUMO

We report a case of a 53-year-old man with a "short RCA" seen coursing within the proximal part of the right atrioventricular (AV) groove and terminating in the mid-portion of the right AV groove and a "long RCA" seen to have a proximal course outside the right AV groove, over the free wall of the right ventricle, where it gave rise to the right ventricular and acute marginal branches before returning to the right AV groove in its distal course. The discussion highlights the need for revisiting the nomenclature of "dual RCA and drawing a distinction between "dual" and "duplicated" RCA.

5.
Eur Heart J Open ; 3(5): oead088, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37744954

RESUMO

Aims: To evaluate a deep-learning model (DLM) for detecting coronary stenoses in emergency room patients with acute chest pain (ACP) explored with electrocardiogram-gated aortic computed tomography angiography (CTA) to rule out aortic dissection. Methods and results: This retrospective study included 217 emergency room patients (41% female, mean age 67.2 years) presenting with ACP and evaluated by aortic CTA at our institution. Computed tomography angiography was assessed by two readers, who rated the coronary arteries as 1 (no stenosis), 2 (<50% stenosis), or 3 (≥50% stenosis). Computed tomography angiography was categorized as high quality (HQ), if all three main coronary arteries were analysable and low quality (LQ) otherwise. Curvilinear coronary images were rated by a DLM using the same system. Per-patient and per-vessel analyses were conducted. One hundred and twenty-one patients had HQ and 96 LQ CTA. Sensitivity, specificity, positive predictive value, negative predictive value (NPV), and accuracy of the DLM in patients with high-quality image for detecting ≥50% stenoses were 100, 62, 59, 100, and 75% at the patient level and 98, 79, 57, 99, and 84% at the vessel level, respectively. Sensitivity was lower (79%) for detecting ≥50% stenoses at the vessel level in patients with low-quality image. Diagnostic accuracy was 84% in both groups. All 12 patients with acute coronary syndrome (ACS) and stenoses by invasive coronary angiography (ICA) were rated 3 by the DLM. Conclusion: A DLM demonstrated high NPV for significant coronary artery stenosis in patients with ACP. All patients with ACS and stenoses by ICA were identified by the DLM.

7.
J Cardiovasc Thorac Res ; 15(1): 65-66, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37342667

RESUMO

We report a case of an 87-year-old man where coronary CT angiography incidentally demonstrated a "split" right coronary artery (RCA) featuring a "split" posterior descending artery. This case focusses on the morphological description of this variant as well as its differentiation from a "dual" or "duplicated" RCA.

8.
Diagnostics (Basel) ; 12(11)2022 Nov 16.
Artigo em Inglês | MEDLINE | ID: mdl-36428873

RESUMO

Immunoglobulin G4-related disease (IgG4-RD) is a systemic immune-mediated fibro-inflammatory disorder. Coronary IgG4-RD has been scarcely reported and may present as "tumor-like" lesions. These pseudo-masses may be underdiagnosed mainly due to a vague clinical picture that can vary from complete lack of symptoms to acute coronary syndrome or sudden cardiac death. Early recognition of coronary IgG4-RD is essential to monitor disease activity and prevent life-threatening complications. We report a comprehensive non-invasive imaging evaluation of a patient affected by coronary IgG4-RD, which was diagnosed as an incidental finding during routine pre-laparoscopic cholecystectomy checkup. Non-invasive imaging revealed the presence of a peri-coronary soft-tissue mass that was stable at 12 months follow-up.

9.
BMC Med Imaging ; 22(1): 49, 2022 03 18.
Artigo em Inglês | MEDLINE | ID: mdl-35303820

RESUMO

BACKGROUND: The acceptance of coronary CT angiogram (CCTA) scans in the management of stable angina has led to an exponential increase in studies performed and reported incidental findings, including pulmonary nodules (PN). Using low-dose CT scans, volumetry tools are used in growth assessment and risk stratification of PN between 5 and 8 mm in diameter. Volumetry of PN could also benefit from the increased temporal resolution of CCTA scans, potentially expediting clinical decisions when an incidental PN is first detected on a CCTA scan, and allow for better resource management and planning in a Radiology department. This study aims to investigate how cardiopulmonary hemodynamic factors impact the volumetry of PN using CCTA scans. These factors include the cardiac phase, vascular distance from the main pulmonary artery (MPA) to the nodule, difference of the MPA diameter between systole and diastole, nodule location, and cardiomegaly presence. MATERIALS AND METHODS: Two readers reviewed all CCTA scans performed from 2016 to 2019 in a tertiary hospital and detected PN measuring between 5 and 8 mm in diameter. Each observer measured each nodule using two different software packages and in systole and diastole. A multiple linear regression model was applied, and inter-observer and inter-software agreement were assessed using intraclass correlation. RESULTS: A total of 195 nodules from 107 patients were included in this retrospective, cross-sectional and observational study. The regression model identified the vascular distance (p < 0.001), the difference of the MPA diameter between systole and diastole (p < 0.001), and the location within the lower or posterior thirds of the field of view (p < 0.001 each) as affecting the volume measurement. The cardiac phase was not significant in the model. There was a very high inter-observer agreement but no reasonable inter-software agreement between measurements. CONCLUSIONS: PN volumetry using CCTA scans seems to be sensitive to cardiopulmonary hemodynamic changes independently of the cardiac phase. These might also be relevant to non-gated scans, such as during PN follow-up. The cardiopulmonary hemodynamic changes are a new limiting factor to PN volumetry. In addition, when a patient experiences an acute or deteriorating cardiopulmonary disease during PN follow-up, these hemodynamic changes could affect the PN growth estimation.


Assuntos
Neoplasias Pulmonares , Nódulos Pulmonares Múltiplos , Nódulo Pulmonar Solitário , Angiografia Coronária , Estudos Transversais , Hemodinâmica , Humanos , Estudos Retrospectivos , Nódulo Pulmonar Solitário/diagnóstico por imagem
10.
J. bras. pneumol ; 48(4): e20220015, 2022. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1375749

RESUMO

ABSTRACT Many health systems have been using coronary CT angiography (CCTA) as a first-line examination for ischaemic heart disease patients in various countries. The rising number of CCTA examinations has led to a significant increase in the number of reported incidental extracardiac findings, mainly in the chest. Pulmonary nodules are the most common incidental findings on CCTA scans, as there is a substantial overlap of risk factors between the population seeking to exclude ischaemic heart disease and those at risk of developing lung cancer (i.e., advanced age and smoking habits). However, most incidental findings are clinically insignificant and actively pursuing them could be cost-prohibitive and submit the patient to unnecessary and potentially harmful examinations. Furthermore, there is little consensus regarding when to report or actively exclude these findings and how to manage them, that is, when to trigger an alert or to immediately refer the patient to a pulmonologist, a thoracic surgeon or a multidisciplinary team. This pictorial essay discusses the current literature on this topic and is illustrated with a review of CCTA scans. We also propose a checklist organised by organ and system, recommending actions to raise awareness of pulmonologists, thoracic surgeons, cardiologists and radiologists regarding the most significant and actionable incidental findings on CCTA scans.


RESUMO Muitos sistemas de saúde têm utilizado a angiotomografia coronariana (ATC) como exame de primeira linha para pacientes com doença cardíaca isquêmica em diversos países. O crescente número de exames de ATC tem levado a um aumento significativo do número de relatos de achados extracardíacos incidentais, principalmente no tórax. Nódulos pulmonares são os achados incidentais mais comuns nas imagens de ATC, pois há uma substancial sobreposição de fatores de risco entre a população que busca a exclusão de doença cardíaca isquêmica e aqueles em risco de desenvolver câncer de pulmão (por exemplo, idade avançada e tabagismo). No entanto, a maioria dos achados incidentais é clinicamente insignificante e seu seguimento ativo pode ter um custo proibitivo e submeter o paciente a exames desnecessários e potencialmente prejudiciais. Além disso, há pouco consenso sobre quando relatar ou ativamente excluir esses achados e como manejá-los, ou seja, quando acionar um alerta ou imediatamente encaminhar o paciente para um pneumologista, um cirurgião torácico ou uma equipe multidisciplinar. Este ensaio pictórico discute a literatura atual sobre esse tópico e é ilustrado com uma revisão de imagens de ATC. Também propomos uma lista de verificação organizada por órgão e sistema, recomendando ações para a conscientização de pneumologistas, cirurgiões torácicos, cardiologistas e radiologistas sobre os achados incidentais mais significativos e acionáveis nas imagens de ATC.

11.
Diseases ; 9(3)2021 Sep 17.
Artigo em Inglês | MEDLINE | ID: mdl-34562969

RESUMO

Congenital coronary artery anomalies are rare but well-described causes of chest pain and, in some cases, link to sudden cardiac death. With the spread of advanced imaging techniques, the number of incidental findings is staggering, but little information has been given in order to rule out potential malignant cases in symptomatic adult patients. Here, we describe a case of an anomalous course of the coronary artery with an acute (<45°) take-off angle, as well as an inter-arterial course between a dilated ascending aorta and a dilated pulmonary artery, and how we could manage this patient in our clinical practice.

12.
Phys Med ; 81: 155-161, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33461028

RESUMO

PURPOSE: The use of coronary computed tomography angiography (CCTA) in children remains limited by patient's irradiation, and motion artefacts impairing image quality. Triggering the acquisition at the appropriate moment, and acquiring only necessary components of the cardiac cycle could overcome these limitations. Yet, optimal cardiac intervals to perform CCTA as a function of heart rate (HR) have not yet been addressed in pediatrics. METHODS: Fifty children with coronary artery anomalies underwent a CCTA on a wide-coverage single-beat CT scanner. Multiple phases from 25% to 85% of the R-R interval were acquired and reconstructed with 10% increments. Two radiologists independently assessed motion artifacts on each cardiac phase using a 4-point semi-quantitative scale. RESULTS: At patient level, the best phase for acquisition was found in diastole for patients with HR ≤ 75 bpm and in systole for patients with HR > 85 bpm. At coronary segments and structures level, median optimal phases were reported at 70%, 80%, 47%, 50%, and 54% of the R-R interval for patients with HR ≤ 60, 61-75, 86-100, 101-130, and >130 bpm respectively. For patients with HR between 76 and 85 bpm, no clear trend could be observed. Optimal acquisition durations represented 10% (2 phases), 20% (3 phases), 50% (multiphase), 20% (3 phases), and 10% (2 phases) of the R-R interval for patients with HR ≤ 60, 61-75, 76-100, 101-130, and >130 bpm, respectively. CONCLUSIONS: Optimal positioning and duration of CCTA acquisition intervals were investigated as a function of children's HR, to reduce motion artifacts and patient's irradiation.


Assuntos
Doença da Artéria Coronariana , Pediatria , Artefatos , Criança , Angiografia por Tomografia Computadorizada , Angiografia Coronária , Eletrocardiografia , Frequência Cardíaca , Humanos , Tomografia Computadorizada por Raios X
13.
Eur Radiol ; 31(7): 5087-5095, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33409772

RESUMO

OBJECTIVE: Cardiac motion and aortic pulsatility can affect the image quality of 3D contrast-enhanced MR angiography (CE-MRA). The addition of ECG gating improves image quality; however, no studies have directly linked image quality improvements to clinically used measures. In this study, we directly compared diameter measurements in the same patient from ECG-gated to non-gated CE-MRA to evaluate the impact of ECG gating upon measurement reproducibility. METHODS: Fifty-three patients, referred for thoracic aortic angiography, were enrolled and underwent both non-gated and ECG-gated CE-MRA. Two readers independently measured vessel diameter, image quality, and vessel sharpness at the sinus of Valsalva (SOV), sinotubular junction (STJX), ascending aorta (AAO), distal aortic arch (DLSA), and descending aorta (DAO). Measurement reliability and reproducibility were compared between methods. RESULTS: Image quality with ECG gating was rated significantly higher at the SOV (3.2 ± 0.9 vs 1.2 ± 1.0, p < 0.0001), STJX (3.4 ± 0.7 vs 1.8 ± 1.0, p < 0.0001), AAO (3.5 ± 0.6 vs 1.7 ± 1.1 p < 0.0001), DLSA (4.0 ± 0.1 vs 3.6 ± 0.7, p = 0.006), and DAO (4.0 ± 0.1 vs 3.4 ± 0.9 p < 0.0001) than for non-gated studies. Bland-Altman analyses demonstrated that inter- and intra-observer variability was significantly smaller for ECG-gated MRA at the SOV and AAO. For the non-gated images at the SOV, the 95% limits of agreement for both inter- and intra-observer variability exceeded the growth-rate cutoff for surgical repair (0.5 cm). At the DAO, variability was similar between the two techniques. CONCLUSION: ECG-gated CE-MRA resulted in improved reproducibility in aortic root and ascending aortic measurements. These data suggest that ECG-gated CE-MRA should be used for the serial assessment of the ascending thoracic aorta. KEY POINTS: • ECG-gated CE-MRA improves the reproducibility and repeatability of measurements of the ascending aorta. • With non-gated CE-MRA, pulsatile motion in the proximal aorta results in significant variability in measurement reproducibility.


Assuntos
Aorta Torácica , Angiografia por Ressonância Magnética , Aorta/diagnóstico por imagem , Meios de Contraste , Eletrocardiografia , Humanos , Reprodutibilidade dos Testes
14.
Eur Radiol ; 30(11): 5794-5804, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32506262

RESUMO

OBJECTIVES: Assessment of thoracic aortic dimensions with non-ECG-triggered contrast-enhanced magnetic resonance angiography (CE-MRA) is accompanied with motion artefacts and requires gadolinium. To avoid both motion artefacts and gadolinium administration, we evaluated the similarity and reproducibility of dimensions measured on ECG-triggered, balanced steady-state free precession (SSFP) MRA as alternative to CE-MRA. METHODS: All patients, with varying medical conditions, referred for thoracic aortic examination between September 2016 and March 2018, who underwent non-ECG-triggered CE-MRA and SSFP-MRA (1.5 T) were retrospectively included (n = 30). Aortic dimensions were measured after double-oblique multiplanar reconstruction by two observers at nine landmarks predefined by literature guidelines. Image quality was scored at the sinus of Valsalva, mid-ascending aorta and mid-descending aorta by semi-automatically assessing the vessel sharpness. RESULTS: Aortic dimensions showed high agreement between non-ECG-triggered CE-MRA and SSFP-MRA (r = 0.99, p < 0.05) without overestimation or underestimation of aortic dimensions in SSFP-MRA (mean difference, 0.1 mm; limits of agreement, - 1.9 mm and 1.9 mm). Intra- and inter-observer variabilities were significantly smaller with SSFP-MRA for the sinus of Valsalva and sinotubular junction. Image quality of the sinus of Valsalva was significantly better with SSFP-MRA, as fewer images were of impaired quality (3/30) than in CE-MRA (21/30). Reproducibility of dimensions was significantly better in images scored as good quality compared to impaired quality in both sequences. CONCLUSIONS: Thoracic aortic dimensions measured on SSFP-MRA and non-ECG-triggered CE-MRA were similar. As expected, SSFP-MRA showed better reproducibility close to the aortic root because of lesser motion artefacts, making it a feasible non-contrast imaging alternative. KEY POINTS: • SSFP-MRA provides similar dimensions as non-ECG-triggered CE-MRA. • Intra- and inter-observer reproducibilities improve for the sinus of Valsalva and sinotubular junction with SSFP-MRA. • ECG-triggered SSFP-MRA shows better image quality for landmarks close to the aortic root in the absence of cardiac motion.


Assuntos
Aorta Torácica/diagnóstico por imagem , Artefatos , Eletrocardiografia/métodos , Imageamento Tridimensional/métodos , Angiografia por Ressonância Magnética/métodos , Adulto , Feminino , Humanos , Masculino , Reprodutibilidade dos Testes , Estudos Retrospectivos
15.
Int J Cardiovasc Imaging ; 36(8): 1551-1557, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32306158

RESUMO

A fluoroscopic view perpendicular to the aortic valve annulus is required during transcatheter aortic valve implantation (TAVI) for obtaining an optimal deployment of the bioprosthesis. By predicting c-arm angulation, pre-procedural MDCT could decrease the number of aortograms, shorten the time of the procedure and reduce the amount of intra-arterial contrast agent. The aim of our study was to assess the accuracy of MDCT in predicting c-arm angulation at the cath. lab. In this single center study, we investigated MDCT prediction of c-arm angulation in patients having undergone a TAVI procedure using SAPIEN 3® (Edwards Lifesciences, USA). Prior to the procedure, an experienced radiologist had reported the angulation using dedicated software (CTreport). After the procedure, a blinded experienced radiologist retrospectively measured the angles using the same method (CTstudy). Interobserver variability was drawn from the comparison between CTreport and CTstudy. Then, the mean angular difference between the predicted MDCT angles (CTstudy) was compared to the working view recorded at the cath. lab. Seventy-nine patients (M/F = 0.65; mean age: 85.2 years ± 5.3) were included. Interobserver variability was 5.9 ± 6.1°. The mean absolute difference between MDCT and fluoroscopy was 8.8 ± 7.1°. The present study showed that MDCT could predict the coplanar fluoroscopic angles prior to TAVI using a balloon-expandable bioprosthesis Sapien 3® placed via a transfemoral approach with a mean angular difference of 8.8 ± 7.1°. Reproducibility was considered good as the mean difference between two independent measures was 5.9 ± 6.1°.


Assuntos
Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Tomografia Computadorizada Multidetectores , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/fisiopatologia , Valvuloplastia com Balão , Bioprótese , Técnicas de Imagem de Sincronização Cardíaca , Eletrocardiografia , Feminino , Próteses Valvulares Cardíacas , Hemodinâmica , Humanos , Masculino , Variações Dependentes do Observador , Valor Preditivo dos Testes , Desenho de Prótese , Reprodutibilidade dos Testes , Estudos Retrospectivos , Substituição da Valva Aórtica Transcateter/instrumentação
16.
Circ Cardiovasc Imaging ; 13(2): e009678, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-32066275

RESUMO

BACKGROUND: Coronary artery calcium scoring only represents a small fraction of all information available in noncontrast cardiac computed tomography (CAC-CT). We hypothesized that an automated pipeline using radiomics and machine learning could identify phenotypic information about high-risk left ventricular hypertrophy (LVH) embedded in CAC-CT. METHODS: This was a retrospective analysis of 1982 participants from the DHS (Dallas Heart Study) who underwent CAC-CT and cardiac magnetic resonance. Two hundred twenty-four participants with high-risk LVH were identified by cardiac magnetic resonance. We developed an automated adaptive atlas algorithm to segment the left ventricle on CAC-CT, extracting 107 radiomics features from the volume of interest. Four logistic regression models using different feature selection methods were built to predict high-risk LVH based on CAC-CT radiomics, sex, height, and body surface area in a random training subset of 1587 participants. RESULTS: The respective areas under the receiver operating characteristics curves for the cluster-based model, the logistic regression model after exclusion of highly correlated features, and the penalized logistic regression models using least absolute shrinkage and selection operators with minimum or one SE λ values were 0.74 (95% CI, 0.67-0.82), 0.74 (95% CI, 0.67-0.81), 0.76 (95% CI, 0.69-0.83), and 0.73 (95% CI, 0.66-0.80) for detecting high-risk LVH in a distinct validation subset of 395 participants. CONCLUSIONS: Ventricular segmentation, radiomics features extraction, and machine learning can be used in a pipeline to automatically detect high-risk phenotypes of LVH in participants undergoing CAC-CT, without the need for additional imaging or radiation exposure. Registration: URL http://www.clinicaltrials.gov. Unique identifier: NCT00344903.


Assuntos
Cálcio/metabolismo , Ventrículos do Coração/diagnóstico por imagem , Hipertrofia Ventricular Esquerda/diagnóstico , Tomografia Computadorizada por Raios X/métodos , Feminino , Ventrículos do Coração/fisiopatologia , Humanos , Hipertrofia Ventricular Esquerda/metabolismo , Hipertrofia Ventricular Esquerda/fisiopatologia , Aprendizado de Máquina , Imagem Cinética por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Curva ROC , Estudos Retrospectivos , Fatores de Risco
17.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-799637

RESUMO

Objective@#To explore the clinical value of cardiac coronary artery tracking and freezing(SSF) in improving the quality of CT coronary images.@*Methods@#A total of 52 patients who underwent coronary angiography(CTA) scan from December 2015 to December 2017 in the Maternal and Child Health Care Hospital of Zhuhai were enrolled.The patients were divided into two groups according to the heart rate of the patients.The heart rate in high heart rate group (24 cases) was>75 beats/min.The heart rate in low heart rate group(28 cases) was ≤75 beats/min.The two groups used the standard algorithm(STD) and SSF technique to reconstruct the image separately.The obtained images were obtained by multiple names.The diagnostician performed the analysis and scored the quality of the coronary image using the LiKert 5-point scoring system.The score of <3 points required CTA examination again to evaluate the value of SSF in improving CT coronary image quality.@*Results@#The STD and SSF image quality scores of the high heart rate group were (2.33±0.87)points and (3.99±0.82)points, respectively, and the difference was statistically significant(t=-7.347, P<0.05). The STD and SSF image quality scores of the low heart rate group were (3.15±1.06)points and (4.23±0.65)points, respectively, and the difference was statistically significant(t=-4.596, P<0.05). The STD and SSF image quality scores between the two groups had statistically significant differences (t=5.723, 7.386, all P<0.05). In the high heart rate group, the image quality scores reconstructed using SSF technique was increased by 71%, which in the low heart rate group was increased by 34%, the difference between the two groups was statistically significant(χ2=9.668, P<0.05).@*Conclusion@#SSF algorithm can improve image quality of CTA, especially in patients with high heart rate.

18.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-824154

RESUMO

Objective To explore the clinical value of cardiac coronary artery tracking and freezing (SSF) in improving the quality of CT coronary images.Methods A total of 52 patients who underwent coronary angiography (CTA) scan from December 2015 to December 2017 in the Maternal and Child Health Care Hospital of Zhuhai were enrolled.The patients were divided into two groups according to the heart rate of the patients .The heart rate in high heart rate group (24 cases) was>75 beats/min.The heart rate in low heart rate group (28 cases) was ≤75 beats/min.The two groups used the standard algorithm ( STD) and SSF technique to reconstruct the image separately.The obtained images were obtained by multiple names.The diagnostician performed the analysis and scored the quality of the coronary image using the LiKert 5-point scoring system.The score of <3 points required CTA examination again to evaluate the value of SSF in improving CT coronary image quality.Results The STD and SSF image quality scores of the high heart rate group were (2.33 ±0.87)points and (3.99 ±0.82)points,respectively,and the difference was statistically significant(t=-7.347,P<0.05).The STD and SSF image quality scores of the low heart rate group were (3.15 ±1.06)points and (4.23 ±0.65)points,respectively,and the difference was statistically significant (t=-4.596,P<0.05).The STD and SSF image quality scores between the two groups had statistically significant differ -ences (t=5.723,7.386,all P<0.05).In the high heart rate group,the image quality scores reconstructed using SSF technique was increased by 71%,which in the low heart rate group was increased by 34%,the difference between the two groups was statistically significant ( χ2 =9.668, P <0.05).Conclusion SSF algorithm can improve image quality of CTA,especially in patients with high heart rate.

19.
Arq. bras. cardiol ; 112(5): 491-498, May 2019. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1011193

RESUMO

Abstract Background: The use of Cardiovascular Implantable Electronic Devices (CIED), such as the Implantable Cardioverter Defibrillator (ICD) and Cardiac Resynchronization Therapy (CRT), is increasing. The number of leads may vary according to the device. Lead placement in the left ventricle increases surgical time and may be associated with greater morbidity after hospital discharge, an event that is often confused with the underlying disease severity. Objective: To evaluate the rate of unscheduled emergency hospitalizations and death after implantable device surgery stratified by the type of device. Methods: Prospective cohort study of 199 patients submitted to cardiac device implantation. The groups were stratified according to the type of device: ICD group (n = 124) and CRT group (n = 75). Probability estimates were analyzed by the Kaplan-Meier method according to the outcome. A value of p < 0.05 was considered significant in the statistical analyses. Results: Most of the sample comprised male patients (71.9%), with a mean age of 61.1 ± 14.2. Left ventricular ejection fraction was similar between the groups (CRT 37.4 ± 18.1 vs. ICD 39.1 ± 17.0, p = 0.532). The rate of unscheduled visits to the emergency unit related to the device was 4.8% in the ICD group and 10.6% in the CRT group (p = 0.20). The probability of device-related survival of the variable "death" was different between the groups (p = 0.008). Conclusions: Patients after CRT implantation show a higher probability of mortality after surgery at a follow-up of less than 1 year. The rate of unscheduled hospital visits, related or not to the implant, does not differ between the groups.


Resumo Fundamento: O uso de dispositivos cardíacos eletrônicos implantáveis (DCEI) como o cardiodesfibrilador (CDI) e terapia de ressincronização cardíaca (TRC) - é cada vez maior. O número de eletrodos de estimulação e desfibrilação varia de acordo com o dispositivo. A colocação do eletrodo no ventrículo esquerdo aumenta o tempo cirúrgico podendo associar-se a maior morbidade no acompanhamento após alta hospitalar, evento muitas vezes confundível com a gravidade da patologia base. Objetivo: Avaliar a taxa de internação não programada na emergência e óbito após cirurgia de dispositivos implantáveis estratificados pelo tipo de aparelho. Métodos: Estudo de coorte prospectivo analisando 199 pacientes submetidos à implante de dispositivos cardíacos. Os grupos foram divididos de acordo com o tipo de dispositivo: CDI (n = 124) e TRC (n = 75). Estimativas de probabilidades foram analisadas pelo método de Kaplan-Meier de acordo com o desfecho. Valor de p < 0,05 foi considerado significativo nas análises estatísticas. Resultados: A maioria da amostra era do sexo masculino (71,9%) - idade média de 61,1 ± 14,2. A fração de ejeção do ventrículo esquerdo foi similar entre os grupos (TRC 37,4 ± 18,1 vs. CDI 39,1 ± 17,0; p = 0,532). A taxa de visita não programada na emergência relacionada ao dispositivo foi de 4,8% no grupo CDI e de 10,6% no grupo TRC (p = 0,20). A probabilidade de sobrevida relacionada ao dispositivo da variável "óbito" mostrou-se diferente entre os grupos (p = 0,008). Conclusões: Paciente após o implante de TRC apresenta maior probabilidade de mortalidade após o procedimento cirúrgico no seguimento menor que 1 ano. A taxa de visita hospitalar não programada, relacionadas ou não ao implante, não difere entre os grupos.


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Arritmias Cardíacas/terapia , Desfibriladores Implantáveis/estatística & dados numéricos , Dispositivos de Terapia de Ressincronização Cardíaca/estatística & dados numéricos , Readmissão do Paciente/estatística & dados numéricos , Fatores de Tempo , Estudos Prospectivos , Seguimentos , Desfibriladores Implantáveis/efeitos adversos , Serviço Hospitalar de Emergência/estatística & dados numéricos , Estimativa de Kaplan-Meier , Dispositivos de Terapia de Ressincronização Cardíaca/efeitos adversos
20.
Circ Cardiovasc Imaging ; 12(2): e008348, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30704282

RESUMO

BACKGROUND: The use of coronary computed tomography (CT) angiography in children with coronary artery anomalies is increasing. However, it remains technically demanding and the need to adapt acquisition parameters to a patient's cardiac characteristics has not yet been addressed. The aim of the study was to prospectively assess the feasibility of personalized multiphasic coronary CT angiography for pediatric patients. METHODS: Fifty pediatric patients (mean age 6.1±4.9 years) with coronary artery anomalies underwent a coronary CT angiography on a wide detector single-source CT equipment. Fifteen different acquisition patterns were used to trigger the acquisition at the best theoretical moment within the cardiac cycle. The appropriate pattern was automatically selected based on the patient's heart rate and heart rate variability, derived from the patient's ECG. Two independent radiologists qualitatively evaluated images. RESULTS: All acquisitions fully answered the clinical question for a mean effective dose of 0.97±0.34 mSv. Image quality qualified as good or excellent in 94% of cases (47/50). No examination was considered as not assessable but 6% (3/50) were scored as adequate for diagnosis. For these 3 patients, motion artifacts were the main cause of average image quality. No significant visual differences were reported between the different coronary arteries (mean score of 3.6 on a 4-point scale). No correlation between image quality and cardiac parameters were reported ( r=-0.19 and r=0.00, respectively for heart rate and heart rate variability). CONCLUSIONS: Personalized multiphasic coronary CT angiography acquisitions could be performed with diagnostic quality for a dose equivalent of <4 months of natural background irradiation. CLINICAL TRIAL REGISTRATION: URL: https://www.clinicaltrials.gov . Unique identifier: NCT03194763.


Assuntos
Angiografia por Tomografia Computadorizada , Angiografia Coronária/métodos , Cardiopatias Congênitas/diagnóstico por imagem , Fatores Etários , Técnicas de Imagem de Sincronização Cardíaca , Criança , Pré-Escolar , Estudos Transversais , Eletrocardiografia , Estudos de Viabilidade , Feminino , Cardiopatias Congênitas/fisiopatologia , Frequência Cardíaca , Humanos , Lactente , Masculino , Variações Dependentes do Observador , Valor Preditivo dos Testes , Estudos Prospectivos , Doses de Radiação , Exposição à Radiação , Interpretação de Imagem Radiográfica Assistida por Computador
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...